EMT

Electromagnetic Force Dynamic and Fatigue Testing System

Test force1 – 5 kN
Test typeTensile, bending & compression tests
DriveElectromagnetic
TypeFloor-standing appliances
IndustriesDynamic

Allows Long Stroke Lengths and Fast and Highly Accurate Testing in a Clean Environment

High-Rigidity Frame

A very rigid loading frame is used that resistant to resonance is used.

Large Testing Table (EMT-1kN)

A larger testing table allows testing of even large samples. Lifting/lowering the crosshead can provide a testing space large enough to install a thermostatic chamber.

Capable of ±20  m Displacement Cycles at a 200 Hz Frequency (EMT-1kN)

Fatigue tests can be done at high frequency, which can signi cantly reduce the overall testing time.

Achieves Stroke Lengths from 0 to 100 mm (±50 mm)

The system can be used for large-displacement and high-speed fatigue testing of rubbers. It also supports tensile and compression testing.

1. Actuator

The electromagnetic actuator is coupled with low-friction bearings to achieve high waveform reproducibility.

2. Electric Crosshead Drive and Manual Clamp Levers

The crosshead can be raised or lowered using an electric switch. The crosshead can be immobilized easily using manual clamp levers.

3. Load cell

4. Emergency stop switch

5. Servo Controller 4830 and Control/Data Analysis Software

The controller allows high-performance and high-functionality dynamic and fatigue testing.

6. Power Amplifier Unit

Internal electronic power circuits are used to drive the electromagnetic actuator. The top surface can be used as a table for the controller.

Dual-Stage Crosshead Drive Mechanism

Using two buttons to operate the crosshead and clamps helps prevent operating errors and accidents.

8. Air-cooling unit (inside main unit)

Amplitude Characteristics (60 Hz)

Applications

Technical data: 1 kN, 5 kN, 3,5 kN

 
 EMT-1kNV-30EMT-1kNV-50EMT-5kNV-30EMT-5kNV-50
Maximum test force

±1 kN

(static and dynamic tests)

±1 kN

(static and dynamic tests)

Dynamic±5kN,

Static±3.5kN

Dynamic±5kN,

Static±3.5kN

Stroke±30mm±50mm±30mm±50mm
Cycle speed and amplitudeSee amplitude characteristics charts.
Max. speed1m/s2m/s1m/s1m/s
Max. frequency200Hz200Hz100Hz100Hz
ControllerServo Controller 4830
Controlled itemsTest force and stroke (two can be added as option)
Test force range and indication accuracyRangeless Within ±0.5 % of indicated value or ±0.02 % of maximum test force
Stroke range and indication accuracyRangeless Within ±1 % of indicated value or ±0.1 % of rated value
Frame drive mechanismElectric
Test spaceDistance between columns: 460 mm Jig mounting spacing: 0 to 700 mm
WeightMain unit: 510 kg Power amplifier: 60 kg Controller: 8 kgMain unit: 1100 kg Power amplifier: 300 kg Controller: 8 kg
Operating noise62 dB (reference value measured 1 m from front of main unit and floor)
Power requirements50/60 Hz, 3-phase, 200 V, 4 kVA50/60 Hz, 3-phase, 200 V, 5 kVA50/60Hz 3-phase 200V 9kVA, Single-phase 100V 300VA
Power consumption at max load4kW5kW5kW6kW
 
Right Menu Icon