{"id":16383,"date":"2024-09-19T10:16:16","date_gmt":"2024-09-19T08:16:16","guid":{"rendered":"https:\/\/dev.shimadzu-testing.com\/?p=16383"},"modified":"2025-02-05T11:21:06","modified_gmt":"2025-02-05T10:21:06","slug":"observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing","status":"publish","type":"post","link":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/","title":{"rendered":"Observing the Fracture of Unidirectional CFRP in Static Tensile Testing"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"16383\" class=\"elementor elementor-16383\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4e15197 e-flex e-con-boxed e-con e-parent\" data-id=\"4e15197\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a8c5eeb elementor-widget elementor-widget-text-editor\" data-id=\"a8c5eeb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><strong>Introduction<\/strong><\/h2>\n<p>Carbon fiber reinforced plastic (CFRP) is a composite material with a particularly high specific strength. It is used in aircraft and in some transport equipment to reduce fuel costs by reducing weight. While it has some excellent mechanical characteristics as a composite material, when in-plane damage occurs it displays brittle failure behavior, with fracture propagating instantly from the point of damage. Consequently, CFRP development involves not only material testing, but also observation of material failure to check for fracture locations at weak points. Furthermore, material failure is observed to evaluate the validity of computer aided engineering (CAE) recently. As mentioned above, a CFRP fracture event occurs extremely quickly and cannot be observed by the naked eye, so a high-speed video camera is used. Shimadzu has published an Application News on this topic in the past (No. V017 Observing the Failure of CFRP Materials in High-Speed Tensile Tests). High-speed tensile testing involves an instantaneous testing time. To accommodate this, a strobe capable of emitting very intense light instantaneously is used to achieve an image capture speed of over 1 million frames\/second. Meanwhile, static testing involves longer testing times with a metal halide lamp used as a light source for continuous lighting (a relatively weak light source compared to a strobe), which cannot produce enough light to capture images at more than 500 thousand frames\/second. The newly developed HPV-X2 camera is 6 times more sensitive than the previous HPV-X camera, which allows it to capture over 1 million frames\/second using even a metal halide lamp as a light source. In this article, we demonstrate the observation of unidirectional CFRP failure in static testing.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6728194 elementor-widget elementor-widget-text-editor\" data-id=\"6728194\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><strong>Measurement <br \/><\/strong><\/h2>\n<p>The AG-Xplus precision universal testing machine and HPV-X2 high-speed video camera were used in experiments. The equipment used is shown in Table 1. Observing material failure during tensile testing requires a signal to trigger the high-speed video camera in time with material failure. Since cracks propagate in the direction of the unidirectional fibers when failure occurs in unidirectional CFRP, we attached aluminum foil perpendicular to the direction of the fibers with adhesive. A specimen with the aluminum foil attached is shown in Fig. 1. A break in conduction through the aluminum foil caused by a break in the specimen triggers observation of the failure event. The failure of unidirectional CFRP is shown in Fig. 4.\nLongitudinal cracks can be seen on the left side of the\nspecimen in image (2) of Fig. 4. In image (3), these\ncracks have propagated as far as the upper tab.\nLongitudinal cracks can also be seen on the right side\nof the sample in image (3). Image (6) is a later view of\nthe sample as it is breaking apart. Using the HPV-X2\nallows for the observation of CFRP failure during static\ntensile tests, which i s useful for future CFRP\ndevelopment.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f968102 elementor-widget elementor-widget-text-editor\" data-id=\"f968102\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><strong>Results <br \/><\/strong><\/h2>\n<p>A view of the test is shown in Fig. 2 and Fig. 3. As shown in Fig. 3, aluminum foil is also attached to the jigs around the specimen in order to focus light onto the specimen. Test conditions are shown in Table 2.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2e696ce e-grid e-con-full e-con e-child\" data-id=\"2e696ce\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5b38999 elementor-widget elementor-widget-image\" data-id=\"5b38999\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-tabele-1-testing-system.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-tabele-1-testing-system\" data-elementor-lightbox-description=\"Table 1 Testing System\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTYzNTMsInVybCI6Imh0dHBzOlwvXC9zaGltYWR6dS10ZXN0aW5nLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDlcL29ic2VydmluZy10aGUtZnJhY3R1cmUtb2YtdW5pZGlyZWN0aW9uYWwtY2ZycC1pbi1zdGF0aWMtdGVuc2lsZS10ZXN0aW5nLXRhYmVsZS0xLXRlc3Rpbmctc3lzdGVtLmpwZyJ9\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"268\" src=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-tabele-1-testing-system-768x268.jpg\" class=\"attachment-medium_large size-medium_large wp-image-16353\" alt=\"Table 1 Testing System\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Table 1 Testing System<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21447e8 elementor-widget elementor-widget-image\" data-id=\"21447e8\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-table-2-test-condiions.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-table-2-test-condiions\" data-elementor-lightbox-description=\"Table 2 Test Condiions\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTYzNTQsInVybCI6Imh0dHBzOlwvXC9zaGltYWR6dS10ZXN0aW5nLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDlcL29ic2VydmluZy10aGUtZnJhY3R1cmUtb2YtdW5pZGlyZWN0aW9uYWwtY2ZycC1pbi1zdGF0aWMtdGVuc2lsZS10ZXN0aW5nLXRhYmxlLTItdGVzdC1jb25kaWlvbnMuanBnIn0%3D\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"768\" height=\"185\" src=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-table-2-test-condiions-768x185.jpg\" class=\"attachment-medium_large size-medium_large wp-image-16354\" alt=\"Table 2 Test Condiions\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Table 2 Test Condiions<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9010cb4 e-grid e-con-full e-con e-child\" data-id=\"9010cb4\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-65662a1 elementor-widget elementor-widget-image\" data-id=\"65662a1\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig2-view-of-the-test.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"Fig. 2 View of the Test\" data-elementor-lightbox-description=\"Fig. 2 View of the Test\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTYzNTEsInVybCI6Imh0dHBzOlwvXC9zaGltYWR6dS10ZXN0aW5nLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDlcL29ic2VydmluZy10aGUtZnJhY3R1cmUtb2YtdW5pZGlyZWN0aW9uYWwtY2ZycC1pbi1zdGF0aWMtdGVuc2lsZS10ZXN0aW5nLWZpZzItdmlldy1vZi10aGUtdGVzdC5qcGcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"768\" height=\"442\" src=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig2-view-of-the-test-768x442.jpg\" class=\"attachment-medium_large size-medium_large wp-image-16351\" alt=\"Fig. 2 View of the Test\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Fig. 2 View of the Test<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75c9033 elementor-widget elementor-widget-image\" data-id=\"75c9033\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-view-of-the-test-magnified-view.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-view-of-the-test-magnified-view\" data-elementor-lightbox-description=\"Fig. 3 View of the Test (Magnified View)\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTYzNTUsInVybCI6Imh0dHBzOlwvXC9zaGltYWR6dS10ZXN0aW5nLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDlcL29ic2VydmluZy10aGUtZnJhY3R1cmUtb2YtdW5pZGlyZWN0aW9uYWwtY2ZycC1pbi1zdGF0aWMtdGVuc2lsZS10ZXN0aW5nLXZpZXctb2YtdGhlLXRlc3QtbWFnbmlmaWVkLXZpZXcuanBnIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"450\" src=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-view-of-the-test-magnified-view-768x450.jpg\" class=\"attachment-medium_large size-medium_large wp-image-16355\" alt=\"Fig. 3 View of the Test (Magnified View)\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Fig. 3 View of the Test (Magnified View)<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f9f726 elementor-widget elementor-widget-image\" data-id=\"1f9f726\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig4-captured-Images-interval-between-captured-images-is-2-\u03bcs.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig4-captured-Images-interval-between-captured-images-is-2-\u03bcs\" data-elementor-lightbox-description=\"Fig. 4 Captured Images (Interval between captured images is 2 \u03bcs.)\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MTYzNTIsInVybCI6Imh0dHBzOlwvXC9zaGltYWR6dS10ZXN0aW5nLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNFwvMDlcL29ic2VydmluZy10aGUtZnJhY3R1cmUtb2YtdW5pZGlyZWN0aW9uYWwtY2ZycC1pbi1zdGF0aWMtdGVuc2lsZS10ZXN0aW5nLWZpZzQtY2FwdHVyZWQtSW1hZ2VzLWludGVydmFsLWJldHdlZW4tY2FwdHVyZWQtaW1hZ2VzLWlzLTItXHUwM2Jjcy5qcGcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"887\" height=\"1024\" src=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig4-captured-Images-interval-between-captured-images-is-2-\u03bcs-887x1024.jpg\" class=\"attachment-large size-large wp-image-16352\" alt=\"Fig. 4 Captured Images (Interval between captured images is 2 \u03bcs.)\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Fig. 4 Captured Images (Interval between captured images is 2 \u03bcs.)<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f5d236 elementor-widget elementor-widget-spacer\" data-id=\"8f5d236\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-167ca2b e-flex e-con-boxed e-con e-parent\" data-id=\"167ca2b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2bb8546 elementor-widget elementor-widget-heading\" data-id=\"2bb8546\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Download<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-951c335 downloads-liste elementor-widget elementor-widget-text-editor\" data-id=\"951c335\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-failure-of-open-hole-cfrp-specimens-in-tensile-tests.pdf\">Application: Observing the Fracture of Unidirectional CFRP in Static Tensile Testing<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-456b591 elementor-widget elementor-widget-spacer\" data-id=\"456b591\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a119d2d elementor-hidden-desktop elementor-hidden-tablet elementor-hidden-mobile elementor-widget elementor-widget-button\" data-id=\"a119d2d\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/tensile-test-of-plastics-with-automatic-extensometer.pdf\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Tensile Test of Plastic with Extensometer (PDF)<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Carbon fiber reinforced plastic (CFRP) is a composite material with a particularly high specific strength. It is used in aircraft and&#8230;<\/p>\n","protected":false},"author":5,"featured_media":16350,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[340,357],"tags":[],"class_list":["post-16383","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-high-speed-video-camera","category-hpv-x2"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Unidirectional CFRP Fracture in Static Tensile Testing | Shimadzu HPV-X2<\/title>\n<meta name=\"description\" content=\"Explore how Shimadzu&#039;s HPV-X2 high-speed video camera captures the fracture behavior of unidirectional CFRP during static tensile tests for detailed analysis.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Unidirectional CFRP Fracture in Static Tensile Testing | Shimadzu HPV-X2\" \/>\n<meta name=\"twitter:description\" content=\"Explore how Shimadzu&#039;s HPV-X2 high-speed video camera captures the fracture behavior of unidirectional CFRP during static tensile tests for detailed analysis.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Theresa\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/\"},\"author\":{\"name\":\"Theresa\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#\/schema\/person\/f686fd51def6b6f4123fff0ca9f2aada\"},\"headline\":\"Observing the Fracture of Unidirectional CFRP in Static Tensile Testing\",\"datePublished\":\"2024-09-19T08:16:16+00:00\",\"dateModified\":\"2025-02-05T10:21:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/\"},\"wordCount\":559,\"publisher\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg\",\"articleSection\":[\"High-speed Video Camera\",\"hpv-x2\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/\",\"url\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/\",\"name\":\"Unidirectional CFRP Fracture in Static Tensile Testing | Shimadzu HPV-X2\",\"isPartOf\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg\",\"datePublished\":\"2024-09-19T08:16:16+00:00\",\"dateModified\":\"2025-02-05T10:21:06+00:00\",\"description\":\"Explore how Shimadzu's HPV-X2 high-speed video camera captures the fracture behavior of unidirectional CFRP during static tensile tests for detailed analysis.\",\"breadcrumb\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#primaryimage\",\"url\":\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg\",\"contentUrl\":\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg\",\"width\":1344,\"height\":699,\"caption\":\"Fig. 1 Test Specimen\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/shimadzu-testing.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Observing the Fracture of Unidirectional CFRP in Static Tensile Testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#website\",\"url\":\"https:\/\/shimadzu-testing.com\/en\/\",\"name\":\"Shimadzu Testing\",\"description\":\"Shimadzu Testing\",\"publisher\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/shimadzu-testing.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#organization\",\"name\":\"Shimadzu Testing\",\"url\":\"https:\/\/shimadzu-testing.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/08\/shimadzu-logo-roter-hintergrund.svg\",\"contentUrl\":\"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/08\/shimadzu-logo-roter-hintergrund.svg\",\"width\":364,\"height\":100,\"caption\":\"Shimadzu Testing\"},\"image\":{\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#\/schema\/person\/f686fd51def6b6f4123fff0ca9f2aada\",\"name\":\"Theresa\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/shimadzu-testing.com\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/55795086200855ac2ac9e1b764ba36ddd0ab52d08f1ad6e50cee74d374d489e5?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/55795086200855ac2ac9e1b764ba36ddd0ab52d08f1ad6e50cee74d374d489e5?s=96&d=mm&r=g\",\"caption\":\"Theresa\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Unidirectional CFRP Fracture in Static Tensile Testing | Shimadzu HPV-X2","description":"Explore how Shimadzu's HPV-X2 high-speed video camera captures the fracture behavior of unidirectional CFRP during static tensile tests for detailed analysis.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/","twitter_card":"summary_large_image","twitter_title":"Unidirectional CFRP Fracture in Static Tensile Testing | Shimadzu HPV-X2","twitter_description":"Explore how Shimadzu's HPV-X2 high-speed video camera captures the fracture behavior of unidirectional CFRP during static tensile tests for detailed analysis.","twitter_image":"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg","twitter_misc":{"Written by":"Theresa","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#article","isPartOf":{"@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/"},"author":{"name":"Theresa","@id":"https:\/\/shimadzu-testing.com\/en\/#\/schema\/person\/f686fd51def6b6f4123fff0ca9f2aada"},"headline":"Observing the Fracture of Unidirectional CFRP in Static Tensile Testing","datePublished":"2024-09-19T08:16:16+00:00","dateModified":"2025-02-05T10:21:06+00:00","mainEntityOfPage":{"@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/"},"wordCount":559,"publisher":{"@id":"https:\/\/shimadzu-testing.com\/en\/#organization"},"image":{"@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg","articleSection":["High-speed Video Camera","hpv-x2"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/","url":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/","name":"Unidirectional CFRP Fracture in Static Tensile Testing | Shimadzu HPV-X2","isPartOf":{"@id":"https:\/\/shimadzu-testing.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#primaryimage"},"image":{"@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg","datePublished":"2024-09-19T08:16:16+00:00","dateModified":"2025-02-05T10:21:06+00:00","description":"Explore how Shimadzu's HPV-X2 high-speed video camera captures the fracture behavior of unidirectional CFRP during static tensile tests for detailed analysis.","breadcrumb":{"@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#primaryimage","url":"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg","contentUrl":"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/09\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing-fig1-test-specimen.jpg","width":1344,"height":699,"caption":"Fig. 1 Test Specimen"},{"@type":"BreadcrumbList","@id":"https:\/\/shimadzu-testing.com\/en\/know-how\/high-speed-video-camera\/observing-the-fracture-of-unidirectional-cfrp-in-static-tensile-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/shimadzu-testing.com\/"},{"@type":"ListItem","position":2,"name":"Observing the Fracture of Unidirectional CFRP in Static Tensile Testing"}]},{"@type":"WebSite","@id":"https:\/\/shimadzu-testing.com\/en\/#website","url":"https:\/\/shimadzu-testing.com\/en\/","name":"Shimadzu Testing","description":"Shimadzu Testing","publisher":{"@id":"https:\/\/shimadzu-testing.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/shimadzu-testing.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/shimadzu-testing.com\/en\/#organization","name":"Shimadzu Testing","url":"https:\/\/shimadzu-testing.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/shimadzu-testing.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/08\/shimadzu-logo-roter-hintergrund.svg","contentUrl":"https:\/\/shimadzu-testing.com\/wp-content\/uploads\/2024\/08\/shimadzu-logo-roter-hintergrund.svg","width":364,"height":100,"caption":"Shimadzu Testing"},"image":{"@id":"https:\/\/shimadzu-testing.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/shimadzu-testing.com\/en\/#\/schema\/person\/f686fd51def6b6f4123fff0ca9f2aada","name":"Theresa","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/shimadzu-testing.com\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/55795086200855ac2ac9e1b764ba36ddd0ab52d08f1ad6e50cee74d374d489e5?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/55795086200855ac2ac9e1b764ba36ddd0ab52d08f1ad6e50cee74d374d489e5?s=96&d=mm&r=g","caption":"Theresa"}}]}},"_links":{"self":[{"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/posts\/16383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/comments?post=16383"}],"version-history":[{"count":0,"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/posts\/16383\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/media\/16350"}],"wp:attachment":[{"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/media?parent=16383"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/categories?post=16383"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shimadzu-testing.com\/en\/wp-json\/wp\/v2\/tags?post=16383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}